Electrodes, MIG and flux-cored wire, TIG rod, submerged arc wire and flux — in stock at Paschim Vihar. On code work the third-party approval decides the purchase, so every approval each product holds is listed.

Stick electrodes (SMAW)
| Product | Classification | Coating | Current | Yield / Tensile | What it's for | |
|---|---|---|---|---|---|---|
| ESAB 28 | AWS E6013 · EN ISO 2560-A E 38 0 RC 11 · IS 814 ERR4212X | Rutile, medium heavy | AC, DC± · min AC OCV 50 | 420 / 510 MPa · 28% | General structural steel, all positions · radiographic quality, low spatter, self-detaching slag | PDFQuote |
| ESAB Ferroarc | AWS E6013 · IS 814 ER4211X | Rutile, medium | AC, DC± · low OCV 50 V | 420 / 500 MPa · 26% | General-purpose mild steel, all positions · runs on low-OCV AC sets · smooth stable arc, low spatter, radiographic quality · 2.5–5.0 mm | PDFQuote |
| ESAB Ferrospeed Plus | AWS E6013 · IS 814 ER4211X | Rutile, medium heavy | AC, DC± · low OCV | 400 / 500 MPa · 27% | All positions, known for superior vertical-down welding · excellent weld finish, radiographic quality · 2.5–5.0 mm | PDFQuote |
| ESAB 36H | AWS E7018 · EN ISO 2560-A E 42 3 B 32 H5 · IS 814 EB5426H3JX | Basic, iron powder | AC, DC+ · min AC OCV 70 | 470 / 550 MPa · 28% | Low hydrogen — <5.0 ml/100 g. Restrained structures, crack-sensitive joints. Must be dried before use | PDFQuote |
| ESAB 36H (SPL) | AWS E7018-1 | Basic, iron powder | AC, DC+ | 500 / 570 MPa · 32% | Low hydrogen, low temperature — <5.0 ml/100 g, 75 J at −46 °C · medium tensile and fine-grained steels · keeps its properties after extended PWHT | PDFQuote |
| PIPEWELD 6010R | AWS E6010 · IS 814 EC4410X | Cellulosic | DC+ only | 440 / 520 MPa · 26% | Deep penetration root runs on pipe. Fast-freezing slag · 2.5 mm 50–80 A, 3.15 mm 80–120 A, 4.0 mm 100–150 A | PDFQuote |
MIG wire, flux-cored wire and TIG rod (GMAW / FCAW / GTAW)
| Product | Classification | Shielding gas | Yield / Tensile | Impact | What it's for | |
|---|---|---|---|---|---|---|
| ESAB MW1 | AWS ER70S-6 · EN ISO 14341-A G 3Si1 · IS 6419 S4-C504 | M21, C1 | 450 / 560 MPa (M21) · 430 / 530 (C1) | — | Copper coated Mn-Si solid wire · general construction, automotive, shipbuilding, pressure vessels · designed for high wire feed speed and high current | PDFQuote |
| OK Autrod 13.14 | AWS ER90S-D2 | C1, M21 | 570 / 650 MPa (C1) · 590 / 690 (M21) | 45 J (C1) · 60 J (M21) at −30 °C | Copper coated 0.5% Mo low-alloy wire for HSLA steels · tractor cylinders, auto components, wagons · RDSO Class III — used on CONCOR wagons · 1.2 mm 120–280 A, 1.6 mm 225–360 A | PDFQuote |
| ESAB 71T1 | AWS E71T1-C1A0-CS2 · EN ISO 17632-A T 42 0 P C 1 H10 | C1 (100% CO₂) | 500 / 550 MPa · 28% | 95 J at 0 °C | Rutile flux-cored wire, all positions, DC+ · slag covers well and lifts easily, weld free of slag inclusions and porosity · 1.2 mm 140–300 A, 1.6 mm 160–410 A | PDFQuote |
| OK TIGROD S2 | AWS ER70S-2 · EN ISO 636-A W 46 3 W2Ti · IS 6419 S1-I504 | I1 (argon) | 460 / 550 MPa · 28% | 120 J at −30 °C | Copper coated Mn-Si TIG rod · light gauge steel in all positions · root runs for pipe and tube | PDFQuote |
Submerged arc wire and flux (SAW)
| Product | Classification | Type | Weld metal with OK Flux 10.71L | Impact | What it's for | |
|---|---|---|---|---|---|---|
| OK Autrod 12.08L | AWS A5.17 EL8/EL12 · EN ISO 14171-A S1 | Copper coated C-Mn · 0.50% Mn | 390 / 450 MPa · 25% (F6A2) | 100 J at −18 °C | Mild and medium tensile steels | PDFQuote |
| OK Autrod 12.22L | AWS A5.17 EM12K · EN ISO 14171-B SU21 | Copper coated, medium Mn, killed · 1.00% Mn | 450 / 540 MPa · 29% (F7A4) | 45 J at −29 °C | Medium and high strength steels | PDFQuote |
| OK Autrod 12.40L | AWS A5.17 EH14 | Copper coated, high Mn, semi-killed · 1.85% Mn | 490 / 580 MPa · 27% (F7A4) | 60 J at −29 °C | Medium and high tensile steels | PDFQuote |
| OK Autrod 12.24L | AWS A5.23 EA2 · IS 7280 AS-2 Mo (nearest) | Copper coated, Mo alloyed · 0.50% Mo | 550 / 610 MPa · 23% (F8A2-EA2-A4) | 65 J at −18 °C | Non-alloyed and low-alloyed steels · RDSO W4 | PDFQuote |
| OK Flux 10.71L | EN ISO 14174 S A AB 1 67 AC H5 | Agglomerated, aluminate-basic · basicity 1.5 | Use with any wire above | — | One flux for all the wires above · single and multi-run, any plate thickness, AC or DC, tandem and twin-arc · structural steel, pressure vessels, wind towers, pipe to X70 · H5 when redried | PDFQuote |
Third-party approvals — the reason these get specified on code work.
| Product | Approvals held |
|---|---|
| ESAB 28 | ABS · BIS · BV · CE EN 13479 · DNV · IBR · IRS · LR · NAKS (2.5–4.0 mm) · PDIL |
| ESAB Ferroarc | ABS 2 · BV 2 · DNV 2 · IBR · IRS 2 · LR 2m |
| ESAB Ferrospeed Plus | ABS 2 · BV 2 · DNV 2 · IBR · IRS 2 · LR 2m · PDIL · M N Dastur |
| ESAB 36H | ABS 3YH5 · BIS · BV 3Y HH · CE · DNV 3YH15 · IBR · IRS 3Y HH · LR 3Y H15 · PDIL · M N Dastur |
| ESAB 36H (SPL) | ABS · IBR · LR 4Y40mH15 · PDIL |
| ESAB MW1 | BIS · CE · DNV III MS/III T · IBR · IRS 2M, 1T · LR 1T, 3S H15 · RDSO Class I |
| OK Autrod 13.14 | RDSO Class III |
| ESAB 71T1 | ABS 2Y400 · BV 2Y40 · DNV IIY40MS · IRS 2Y40SM · LR 2Y |
| OK TIGROD S2 | BIS · CE EN 13479 · IBR · PDIL |
| PIPEWELD 6010R | PDIL |
| OK Autrod 12.08L | ABS · IRS (with OK Flux 10.71L) |
| OK Autrod 12.22L | LR (with OK Flux 10.71L) |
| OK Autrod 12.40L | IBR · IRS · LR · M N Dastur (with OK Flux 10.71L) |
| OK Autrod 12.24L | RDSO W4 |
Approvals are the whole argument on code work. If your customer builds pressure vessels, ships or railway stock, the consumable has to carry the right approval — IBR for boilers, LR / DNV / ABS for marine, RDSO for Indian Railways. That is why a cheaper unapproved electrode is not actually cheaper. Tell us the code you're working to and we'll match the consumable → Bulk and repeat-order rates available.
Our own footage, filmed on the shop floor at Paschim Vihar and on customer sites — not manufacturer marketing. Nothing loads from YouTube until you press play.
More machines at work on our channel: youtube.com/@arcweldingcom
Material, thickness, quantity and delivery location are all we need to begin. We represent seven authorised brands, so the recommendation you receive is the one the job calls for.